ultrafleXtreme

The enhanced ultrafleXtreme: the industry standard MALDI-TOF/TOF mass spectrometer with 5 GS/s 10 bit digitizer for enhanced resolution and dynamic range

Superior performance. Next-generation MALDI-TOF and TOF/TOF technology

ultrafleXtreme

ultrafleXtreme

Redefine MALDI-TOF/TOF performance

High content data
Full MS/MS data sets can be acquired with up to 1000 Hz laser repetition rate from low fmol levels within seconds.
Confidence
Dedicated software analyzes and visualizes the high content data automatically, generating results with high confidence identifications.
Flexibility
The well-established proprietary smartbeam-II laser provides unprecedented analytical and matrix flexibility in diverse workflows.
ultrafleXtreme

Fast and direct results for efficient research

  • Bruker's patented innovative smartbeam-II laser enables high data acquisition speed in both MS and MS/MS at full systems performance. The well-established proprietary smartbeam-II laser provides unprecedented analytical and matrix flexibility in workflows from protein tissue imaging, intact proteins analysis, glycoproteomics, biologics or oligo QC, polymer analysis, to LC-MALDI proteomics and TLC-MALDI – all fully enabled at 1-2000 Hz repetition rates.
  • Broadband mass resolving power up to 40,000 enables precision proteomics via Bruker’s unique PAN technology for highest mass resolution across a very broad mass range, not just at a selected optimum.
  • The FlashDetector combined with a 5 GS/s 10-bit digitizer and latest advances in electronics provide mass resolving power up to 40,000 and 1 ppm mass accuracy for highest confidence.
  • The IR-laser based self-cleaning ion source ensures robust, long-term highest-performance operation. Very long MALDI laser lifetime in combination with automated source cleaning in just minutes leads to high uptime and low maintenance costs.
  • Typically, full MS/MS data sets can be acquired with up to 1000 Hz laser repetition rate from low fmol levels within seconds. The Bruker bioinformatics software is perfectly adapted to analyze and visualize the match between the raw spectra and annotated peptide and protein structures.
ultrafleXtreme

Proven technology taken to the next level

Attain the highest level of mass spectrometry performance with the enhanced ultrafleXtreme, an instrument exceeding all your expectations.

Combining true 2 kHz speed in TOF mode and 1 kHz in TOF/TOF mode with a 10-bit digitizer for enhanced dynamic range and extreme flexibility for a broad variety of complementary research, biopharmaceutical, proteomics and applied applications.

  • QC and MALDI assays with unmatched return of results and investment
  • Measure protein assays with 1-2% CV
  • Non-biased polymer analysis yielding true polymer distributions with a single click using PolyTools software
  • High definition MALDI Imaging data acquisition combined with SCiLS™ Lab software to support your challenging research
  • Industry leading in Top-Down protein sequencing fully compatible with BioPharma Compass® solution
  • Conquer peptide and protein samples too difficult for ESI
  • Proteins can be identified with high confidence with unmatched ease

 

ultrafleXtreme

Fast results for efficient biopharma research

Applications such as in-depth characterization of biopharmaceuticals and tissue imaging benefit from a multitude of technology innovations and solutions.

  • Industry leading in Top-Down protein sequencing fully compatible with BioPharma Compass® solution
  • Advanced Peptide and Protein analysis:
    Conquer peptide and protein samples too difficult for ESI, e.g. membrane proteins, which do not ionize well using ESI. Proteins can be identified with high confidence with unmatched ease.
  • Oligo QC at unparalleled pace with MALDI and BioPharma Compass®
  • Polymer Analysis:
    Unlike electrospray mass spectrometers, which utilize ion guides to send ions towards detectors, axial MALDI-TOF instruments have minimal ion optics. As ion guides are tuned for optimal transmission of certain mass ranges, polymer distributions can be shifted. This is far less the case with axial MALDI-TOF instruments rendering them as ideal polymer analysis technology. All important polymer parameters, such as average molecular weights (Mn and Mw), dispersity Đ, degree of polymerization, and the mass of the combined end groups, are quickly determined. MALDI-TOF/TOF spectra acquired with the enhanced ultrafleXtreme allow for single end group analysis.
  • High definition MALDI Imaging data acquisition combined with SCiLS™ Lab software to support your challenging research.

SPECIFICATIONS